We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

Electrodes & Probes

Replacement pH electrodes and temperature probes: Ohaus, Mettler Toledo, Eutech and Bante electrodes, and Testo immersion, needle and fiberglass probes. Tell us your meter model and we will match the connector for a free quotation.

TL;DR

Replacement pH electrodes and probes, matched to your meter

We supply replacement pH, ORP and conductivity electrodes and temperature probes in Thailand, including the OHAUS ST310 3-in-1 and METTLER TOLEDO LE438. Send the meter model first: the connector decides whether an electrode works, and the sample decides the junction and body. Every item is quoted on request.

320 products · page 6 of 6

Wire NTC Thermistor Probe

Hanna

Wire NTC Thermistor Probe

MX-12383

GP-03 Teflon-Coated Air Temperature Probe

GP-03 Teflon-Coated Air Temperature Probe

MX-10745

LK-02 Temperature Immersion Probe

LK-02 Temperature Immersion Probe

MX-10099

NK-01 Temperature Needle Probe

NK-01 Temperature Needle Probe

MX-10098

Temperature Probe 20 cm S/S

Temperature Probe 20 cm S/S

MX-10405

HI1293 – pH Electrode

Hanna

HI1293 – pH Electrode

MX-11681

HI7077L – Oil and Fats – 500ml

Hanna

HI7077L – Oil and Fats – 500ml

MX-12257

HI76301D Four ring Conductivity probe

Hanna

HI76301D Four ring Conductivity probe

MX-12384

HI76301W Four ring Conductivity probe

Hanna

HI76301W Four ring Conductivity probe

MX-12385

HI76302W Four ring Conductivity probe with internal temperature sensor

Hanna

HI76302W Four ring Conductivity probe with internal temperature sensor

MX-12386

SI Analytics 285092329 Electrode

SI Analytics

SI Analytics 285092329 Electrode

MX-20381

SI Analytics 285092337 Electrode

SI Analytics

SI Analytics 285092337 Electrode

MX-20382

WTW Wissenschaftlich-Technische Werkstatten GmbH 103635 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103635 Electrode

MX-21030

WTW Wissenschaftlich-Technische Werkstatten GmbH 103642 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103642 Electrode

MX-21031

WTW Wissenschaftlich-Technische Werkstatten GmbH 103643 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103643 Electrode

MX-21032

WTW Wissenschaftlich-Technische Werkstatten GmbH 103646 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103646 Electrode

MX-21033

WTW Wissenschaftlich-Technische Werkstatten GmbH 103650 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103650 Electrode

MX-21034

WTW Wissenschaftlich-Technische Werkstatten GmbH 103780 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103780 Electrode

MX-21035

WTW Wissenschaftlich-Technische Werkstatten GmbH 103806 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103806 Electrode

MX-21036

WTW Wissenschaftlich-Technische Werkstatten GmbH 103814 Electrode

WTW Wissenschaftlich-Technische Werkstatten GmbH

WTW Wissenschaftlich-Technische Werkstatten GmbH 103814 Electrode

MX-21037

Electrode selection guide

How to choose a pH electrode or probe

01

Meter and connector

State the meter model and the connector: BNC, DIN, Quick Connect DIN, RCA or a digital sensor. A meter expecting a digital electrode will not read an analogue one, and a mismatched connector makes an otherwise correct electrode unusable.

02

Sample and junction design

Describe the sample, not only the parameter. A double-junction reference places a second barrier between the reference electrolyte and samples carrying sulfides, proteins or heavy metals that would poison a single junction. Samples with solids or high viscosity call for an open junction or a clog-prevention design.

03

Body material and tip shape

Glass bodies resist solvents and are the general laboratory choice; plastic bodies are used where breakage is a hazard, in the field, or in food production. Flat and spear tips exist for surfaces and semi-solids, where a conventional bulb cannot make proper contact.

04

Temperature measurement

Say whether temperature compensation must come from the electrode itself or from a separate probe. A built-in sensor removes an item from the bench but ties temperature and pH to one replacement cycle.

05

Maintenance and consumables

An electrode is a consumable with a service life, not a permanent fitting. Budget storage solution, the correct filling solution for refillable types, cleaning solutions matched to the fouling, and membrane caps where a dissolved oxygen probe is used.

Include this in an electrode request

  • Meter model and connector type
  • Parameter: pH, ORP, conductivity, DO or ISE
  • Sample description, including solids and viscosity
  • Temperature range and whether compensation is required
  • Single or double junction, refillable or gel-filled
  • Storage, filling and cleaning solutions

Common electrode questions

Will any pH electrode fit my meter?

No. The connector (BNC, DIN, Quick Connect or a digital sensor) decides compatibility before any other property of the electrode. Send the meter model with the request and this gets checked first.

Single or double junction: how do I choose?

From the sample. A double junction adds a barrier between the reference electrolyte and the sample, which is the usual choice where sulfides, proteins or heavy metals are present and would poison a single-junction reference.

Glass body or plastic body?

Glass is the general laboratory choice for chemical resistance. Plastic is used where breakage is a hazard, in the field, or in food production. Body material is a separate question from tip shape, which follows the physical form of the sample.

How long should a pH electrode last?

It is a consumable, and service life depends on the sample, temperature and storage rather than a fixed period. Keep storage solution on hand: a pH electrode should never be left dry or standing in deionised water, as both shorten its life.

What the electrode connects to

Buying notes

Nothing above restates a manufacturer specification. Junction design, body material, operating range and service life are specific to the electrode, and compatibility is confirmed against the meter and sample you give us.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.