We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

Electrodes & Probes

Replacement pH electrodes and temperature probes: Ohaus, Mettler Toledo, Eutech and Bante electrodes, and Testo immersion, needle and fiberglass probes. Tell us your meter model and we will match the connector for a free quotation.

TL;DR

Replacement pH electrodes and probes, matched to your meter

We supply replacement pH, ORP and conductivity electrodes and temperature probes in Thailand, including the OHAUS ST310 3-in-1 and METTLER TOLEDO LE438. Send the meter model first: the connector decides whether an electrode works, and the sample decides the junction and body. Every item is quoted on request.

320 products · page 4 of 6

In-line pH Electrode with PVC Body and BNC Connector

Hanna

In-line pH Electrode with PVC Body and BNC Connector

MX-12940

Inductive Conductivity Probe for HI720

Hanna

Inductive Conductivity Probe for HI720

MX-12941

Industrial Flat Tip pH Electrodes

Hanna

Industrial Flat Tip pH Electrodes

MX-12942

Interchangeable Handle for Thermocouple Probes

Hanna

Interchangeable Handle for Thermocouple Probes

MX-12428

LE438 Plastic-Body pH Electrode

Mettler Toledo

LE438 Plastic-Body pH Electrode

MX-10320

Liquid Membrane ISE Sensor Handle

Hanna

Liquid Membrane ISE Sensor Handle

MX-11884

Multiparameter (pH/DO) Probe for HI98196

Hanna

Multiparameter (pH/DO) Probe for HI98196

MX-12451

Multiparameter (pH/EC) Probe for HI98195

Hanna

Multiparameter (pH/EC) Probe for HI98195

MX-12450

Multiparameter (pH/EC/DO) Probe for HI98194

Hanna

Multiparameter (pH/EC/DO) Probe for HI98194

MX-12989

Multiparameter Digital pH, ORP, Temperature Probe

Hanna

Multiparameter Digital pH, ORP, Temperature Probe

MX-12988

Multiparameter pH/EC/Turbidity/opdo Probe for HI98594

Hanna

Multiparameter pH/EC/Turbidity/opdo Probe for HI98594

MX-12990

opdo Probe Cap Kit

Hanna

opdo Probe Cap Kit

MX-13008

Optical Dissolved Oxygen (DO) Probe

Hanna

Optical Dissolved Oxygen (DO) Probe

MX-13009

Optical DO Process Smart Probe

Hanna

Optical DO Process Smart Probe

MX-13011

Optical OPDO Sensor for HI7698594

Hanna

Optical OPDO Sensor for HI7698594

MX-13012

ORP and Temperature Industrial Smart Probes

Hanna

ORP and Temperature Industrial Smart Probes

MX-13014

ORP Electrode with Clogging Prevention System (CPS) and BNC Connector, 0.5 m Cable

Hanna

ORP Electrode with Clogging Prevention System (CPS) and BNC Connector, 0.5 m Cable

MX-11743

ORP Electrode with Clogging Prevention System (CPS<sup>TM</sup>) and BNC Connector

Hanna

ORP Electrode with Clogging Prevention System (CPS™) and BNC Connector

MX-11744

ORP Electrode with CPS (Clogging Prevention System) for Non-aqueous Titrations

Hanna

ORP Electrode with CPS (Clogging Prevention System) for Non-aqueous Titrations

MX-11745

ORP/temperature electrode with PEI body and single junction

Hanna

ORP/temperature electrode with PEI body and single junction

MX-13017

P11 Refillable pH Electrode

Bante

P11 Refillable pH Electrode

MX-10684

PEI Body pH Electrode with Calomel References with BNC Connector

Hanna

PEI Body pH Electrode with Calomel References with BNC Connector

MX-11691

PEI Body pH Half-Cell Electrode with BNC Connector

Hanna

PEI Body pH Half-Cell Electrode with BNC Connector

MX-11723

Penetration Extended Length K-Type Thermocouple Probe with Handle

Hanna

Penetration Extended Length K-Type Thermocouple Probe with Handle

MX-12420

pH and Temperature Industrial Smart Probes

Hanna

pH and Temperature Industrial Smart Probes

MX-13047

pH Electrode Fill Electrolyte Solution – HI7082L

Hanna

pH Electrode Fill Electrolyte Solution – HI7082L

MX-11486

pH Electrode for Beer Analysis

Hanna

pH Electrode for Beer Analysis

MX-11504

pH Electrode for Beer Analysis with Quick Connect DIN

Hanna

pH Electrode for Beer Analysis with Quick Connect DIN

MX-13061

pH Electrode for Direct Cheese Measurements (use w/ HI98165)

Hanna

pH Electrode for Direct Cheese Measurements (use w/ HI98165)

MX-13063

pH Electrode for Direct Cheese Measurements (use w/ HI99165)

Hanna

pH Electrode for Direct Cheese Measurements (use w/ HI99165)

MX-13062

pH Electrode for Direct Soil Measurement 1

Hanna

pH Electrode for Direct Soil Measurement 1

MX-13064

pH Electrode for Drinking Water

Hanna

pH Electrode for Drinking Water

MX-11505

pH Electrode for Drinking Water with Quick Connect DIN

Hanna

pH Electrode for Drinking Water with Quick Connect DIN

MX-13066

pH Electrode for use with HI207 and HI208

Hanna

pH Electrode for use with HI207 and HI208

MX-13067

pH Electrode for use with HI9214N

Hanna

pH Electrode for use with HI9214N

MX-13068

pH Electrode for Vials and Test Tubes with BNC + PIN Connector

Hanna

pH Electrode for Vials and Test Tubes with BNC + PIN Connector

MX-13069

pH Electrode Storage Cap with Compression Fitting (5 pcs)

Hanna

pH Electrode Storage Cap with Compression Fitting (5 pcs)

MX-13070

pH Electrode Storage Cap with Compression Fitting, 8 mm Stem Diameter (5 pcs.)

Hanna

pH Electrode Storage Cap with Compression Fitting, 8 mm Stem Diameter (5 pcs.)

MX-13071

pH Electrode Storage Cap with Compression Fitting, Titanium Stem (5 pcs.)

Hanna

pH Electrode Storage Cap with Compression Fitting, Titanium Stem (5 pcs.)

MX-13072

pH Electrode Storage Solution – HI70300L

Hanna

pH Electrode Storage Solution – HI70300L

MX-13252

pH Electrode with Built-In Temperature Sensor and DIN Connector

Hanna

pH Electrode with Built-In Temperature Sensor and DIN Connector

MX-11700

pH Electrode with Clogging Prevention System (CPS) and BNC + RCA Connector

Hanna

pH Electrode with Clogging Prevention System (CPS) and BNC + RCA Connector

MX-13074

pH Electrode with Clogging Prevention System (CPS) and BNC Connector

Hanna

pH Electrode with Clogging Prevention System (CPS) and BNC Connector

MX-11652

pH Electrode with Clogging Prevention System (CPS) and BNC Connector (0.5m Cable)

Hanna

pH Electrode with Clogging Prevention System (CPS) and BNC Connector (0.5m Cable)

MX-13075

pH Electrode with Clogging Prevention System (CPS) and Quick DIN Connector

Hanna

pH Electrode with Clogging Prevention System (CPS) and Quick DIN Connector

MX-13076

pH Electrode with Clogging Prevention System (CPS) and Screw Connector

Hanna

pH Electrode with Clogging Prevention System (CPS) and Screw Connector

MX-13077

pH Electrode with Conical Tip and BNC + Pin Connector

Hanna

pH Electrode with Conical Tip and BNC + Pin Connector

MX-11657

pH Electrode with Conical Tip and Quick Connect DIN Connector

Hanna

pH Electrode with Conical Tip and Quick Connect DIN Connector

MX-11655

pH Electrode with CPS (Clogging Prevention System) for Non-aqueous Titrations

Hanna

pH Electrode with CPS (Clogging Prevention System) for Non-aqueous Titrations

MX-11178

pH Electrode with Micro Bulb and BNC + Pin Connector

Hanna

pH Electrode with Micro Bulb and BNC + Pin Connector

MX-12982

pH/EC/°C Multiparameter Probe for HI 9811-5, HI 9812-5 & HI 9813-5

Hanna

pH/EC/°C Multiparameter Probe for HI 9811-5, HI 9812-5 & HI 9813-5

MX-13096

pH/EC/°C Multiparameter Probe for HI 991300 & HI 991301

Hanna

pH/EC/°C Multiparameter Probe for HI 991300 & HI 991301

MX-13097

pH/EC/TDS Multiparameter Probe for use with HI9814

Hanna

pH/EC/TDS Multiparameter Probe for use with HI9814

MX-11677

pH/EC/TDS Multiparameter Probe with CAL Check

Hanna

pH/EC/TDS Multiparameter Probe with CAL Check

MX-11676

pH/EC/TDS Multiparameter Probe with Quick DIN

Hanna

pH/EC/TDS Multiparameter Probe with Quick DIN

MX-13058

pH/EC/TDS/Temperature Probe with CAL Check

Hanna

pH/EC/TDS/Temperature Probe with CAL Check

MX-13060

Pipe Clamp K-Type Thermocouple Probe

Hanna

Pipe Clamp K-Type Thermocouple Probe

MX-12439

Polarographic Dissolved Oxygen (DO) Probe

Hanna

Polarographic Dissolved Oxygen (DO) Probe

MX-13116

Polarographic Dissolved Oxygen Probe

Hanna

Polarographic Dissolved Oxygen Probe

MX-13250

Polarographic Dissolved Oxygen Probe with Protective Sleeve

Hanna

Polarographic Dissolved Oxygen Probe with Protective Sleeve

MX-13251

Electrode selection guide

How to choose a pH electrode or probe

01

Meter and connector

State the meter model and the connector: BNC, DIN, Quick Connect DIN, RCA or a digital sensor. A meter expecting a digital electrode will not read an analogue one, and a mismatched connector makes an otherwise correct electrode unusable.

02

Sample and junction design

Describe the sample, not only the parameter. A double-junction reference places a second barrier between the reference electrolyte and samples carrying sulfides, proteins or heavy metals that would poison a single junction. Samples with solids or high viscosity call for an open junction or a clog-prevention design.

03

Body material and tip shape

Glass bodies resist solvents and are the general laboratory choice; plastic bodies are used where breakage is a hazard, in the field, or in food production. Flat and spear tips exist for surfaces and semi-solids, where a conventional bulb cannot make proper contact.

04

Temperature measurement

Say whether temperature compensation must come from the electrode itself or from a separate probe. A built-in sensor removes an item from the bench but ties temperature and pH to one replacement cycle.

05

Maintenance and consumables

An electrode is a consumable with a service life, not a permanent fitting. Budget storage solution, the correct filling solution for refillable types, cleaning solutions matched to the fouling, and membrane caps where a dissolved oxygen probe is used.

Include this in an electrode request

  • Meter model and connector type
  • Parameter: pH, ORP, conductivity, DO or ISE
  • Sample description, including solids and viscosity
  • Temperature range and whether compensation is required
  • Single or double junction, refillable or gel-filled
  • Storage, filling and cleaning solutions

Common electrode questions

Will any pH electrode fit my meter?

No. The connector (BNC, DIN, Quick Connect or a digital sensor) decides compatibility before any other property of the electrode. Send the meter model with the request and this gets checked first.

Single or double junction: how do I choose?

From the sample. A double junction adds a barrier between the reference electrolyte and the sample, which is the usual choice where sulfides, proteins or heavy metals are present and would poison a single-junction reference.

Glass body or plastic body?

Glass is the general laboratory choice for chemical resistance. Plastic is used where breakage is a hazard, in the field, or in food production. Body material is a separate question from tip shape, which follows the physical form of the sample.

How long should a pH electrode last?

It is a consumable, and service life depends on the sample, temperature and storage rather than a fixed period. Keep storage solution on hand: a pH electrode should never be left dry or standing in deionised water, as both shorten its life.

What the electrode connects to

Buying notes

Nothing above restates a manufacturer specification. Junction design, body material, operating range and service life are specific to the electrode, and compatibility is confirmed against the meter and sample you give us.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.