We use cookies to improve this site and see how it is used. Cookies Policy

Skip to content
ไทย

Electrodes & Probes

Replacement pH electrodes and temperature probes: Ohaus, Mettler Toledo, Eutech and Bante electrodes, and Testo immersion, needle and fiberglass probes. Tell us your meter model and we will match the connector for a free quotation.

TL;DR

Replacement pH electrodes and probes, matched to your meter

We supply replacement pH, ORP and conductivity electrodes and temperature probes in Thailand, including the OHAUS ST310 3-in-1 and METTLER TOLEDO LE438. Send the meter model first: the connector decides whether an electrode works, and the sample decides the junction and body. Every item is quoted on request.

320 products · page 3 of 6

HI3618D – ORP/°C Electrode

Hanna

HI3618D – ORP/°C Electrode

MX-11755

HI4000-51 Gas Sensor Replacement pH for Ammonia Sensor

Hanna

HI4000-51 Gas Sensor Replacement pH for Ammonia Sensor

MX-11885

HI4000-54 Gas sensor replacement pH for Carbon Dioxide Sensor

Hanna

HI4000-54 Gas sensor replacement pH for Carbon Dioxide Sensor

MX-11887

HI4004 – Flüssigmembranelektrode, Halbzelle

Hanna

HI4004 – Calcium Liquid Membrane Electrode, Half-Cell

MX-11902

HI4012 – Feststoffelektrode, Halbzelle

Hanna

HI4012 – Feststoffelektrode, Halbzelle

MX-11923

HI4014 – Potassium Half-Cell ISE

Hanna

HI4014 – Potassium Half-Cell ISE

MX-11932

HI4109 – Feststoffelektrode, kombiniert

Hanna

HI4109 – Feststoffelektrode, kombiniert

MX-11950

HI4430B – ORP Electrode

Hanna

HI4430B – ORP Electrode

MX-11958

HI5110B – ORP Half Cell (Argentometric titration)

Hanna

HI5110B – ORP Half Cell (Argentometric titration)

MX-12024

HI5313 – Reference Electrode, Banana

Hanna

HI5313 – Reference Electrode, Banana

MX-12033

HI5412 – Reference Electrode, Banana

Hanna

HI5412 – Reference Electrode, Banana

MX-12036

HI6100205 – AmpHel Flat Tip (Acid with Fluoride ions) Process pH Electrode

Hanna

HI6100205 – AmpHel Flat Tip (Acid with Fluoride ions) Process pH Electrode

MX-12077

HI6100405 – AmpHel Flat Tip Process pH Electrode

Hanna

HI6100405 – AmpHel Flat Tip Process pH Electrode

MX-12078

HI61014xx – AmpHel Flat Tip PT100 Process pH Electrode

Hanna

HI61014xx – AmpHel Flat Tip PT100 Process pH Electrode

MX-12080

HI6200405 – AmpHel Process ORP Electrode

Hanna

HI6200405 – AmpHel Process ORP Electrode

MX-12083

HI7041x Refilling Solution for Polarographic Probe

Hanna

HI7041x Refilling Solution for Polarographic Probe

MX-12197

HI70621L – Grease & sebum (Cosmetic) – 500ml

Hanna

HI70621L – Grease & sebum (Cosmetic) – 500ml

MX-12222

HI70636L – Wine Stains – 500ml

Hanna

HI70636L – Wine Stains – 500ml

MX-12227

HI70642L – Cheese – 500ml

Hanna

HI70642L – Cheese – 500ml

MX-12230

HI70663L – Soil Deposit – 500ml

Hanna

HI70663L – Soil Deposit – 500ml

MX-12231

HI70671L – Algae, fungi and bateria – 500ml

Hanna

HI70671L – Algae, fungi and bateria – 500ml

MX-12234

HI70681L – Ink Stains – 500ml

Hanna

HI70681L – Ink Stains – 500ml

MX-12235

HI7073L – Proteins – 500ml

Hanna

HI7073L – Proteins – 500ml

MX-12251

HI72911x – pH/°C-Electrode

Hanna

HI72911x – pH/°C-Electrode

MX-12318

HI7609829-0 – pH Sensor for HI9829 Multiparameter

Hanna

HI7609829-0 – pH Sensor for HI9829 Multiparameter

MX-12357

HI7609829-1 – pH / ORP Sensor for HI9829 Multiparameter

Hanna

HI7609829-1 – pH / ORP Sensor for HI9829 Multiparameter

MX-12358

HI7609829-11 – Chloride ISE for HI9829 Multiparameter

Hanna

HI7609829-11 – Chloride ISE for HI9829 Multiparameter

MX-12360

HI7609829-12 – Nitrate ISE for HI9829 Multiparameter

Hanna

HI7609829-12 – Nitrate ISE for HI9829 Multiparameter

MX-12361

HI7609829-2 – Dissolved Oxygen Sensor for HI9829 Multiparameter

Hanna

HI7609829-2 – Dissolved Oxygen Sensor for HI9829 Multiparameter

MX-12362

HI7609829-3 – Conductivity Sensor for HI9829 Multiparameter-Copy

Hanna

HI7609829-3 – Conductivity Sensor for HI9829 Multiparameter-Copy

MX-12363

HI7609829/4 – HI9829 Non Logging Probe without protection shield and sensors

Hanna

HI7609829/4 – HI9829 Non Logging Probe without protection shield and sensors

MX-12365

HI7610 – Pt100 Temperature Sensor – 5m

Hanna

HI7610 – Pt100 Temperature Sensor – 5m

MX-12367

HI7629829/4 – HI9829 Logging Probe without protection shield and sensors with 4m Cable

Hanna

HI7629829/4 – HI9829 Logging Probe without protection shield and sensors with 4m Cable

MX-12376

HI762PWL NTC-Type, Thermistor Probe for semi-solid samples

Hanna

HI762PWL NTC-Type, Thermistor Probe for semi-solid samples

MX-12382

HI76309 Platinum, four ring Conductivity/TDS probe

Hanna

HI76309 Platinum, four ring Conductivity/TDS probe

MX-12388

HI763100 Digital conductivity electrode – 4 ring, platinum (edge)

Hanna

HI763100 Digital conductivity electrode – 4 ring, platinum (edge)

MX-12389

HI7635 – Industrial Conductivity Probe

Hanna

HI7635 – Industrial Conductivity Probe

MX-12392

HI7639 – Inline Conductivity Probes with Platium Ring with PT100 sensor

Hanna

HI7639 – Inline Conductivity Probes with Platium Ring with PT100 sensor

MX-12394

HI76407A/P DO Membrane for probe HI 76407 (5 pcss)

Hanna

HI76407A/P DO Membrane for probe HI 76407 (5 pcss)

MX-12398

HI76409/4 Galvanic DO Probe with Protective Cap

Hanna

HI76409/4 Galvanic DO Probe with Protective Cap

MX-12401

HI76409A/P DO Membrane for probe HI 76409 (5 pcs)

Hanna

HI76409A/P DO Membrane for probe HI 76409 (5 pcs)

MX-12402

HI766A K-Type, Roller Surface Probe w Cable

Hanna

HI766A K-Type, Roller Surface Probe w Cable

MX-12413

HI766B K-Type, Surface Probe

Hanna

HI766B K-Type, Surface Probe

MX-12414

HI766B1 K-Type, 90 Angle Surface Probe

Hanna

HI766B1 K-Type, 90 Angle Surface Probe

MX-12415

HI766C K-Type, Peneratration Probe

Hanna

HI766C K-Type, Peneratration Probe

MX-12418

HI766D K-Type, Air and Gas Probe

Hanna

HI766D K-Type, Air and Gas Probe

MX-12421

HI766E1 K-Type, General Purpose w Cable

Hanna

HI766E1 K-Type, General Purpose w Cable

MX-12422

HI766E2 K-Type, General Purpose w Cable

Hanna

HI766E2 K-Type, General Purpose w Cable

MX-12423

HI766F K-Type, High Temperature Probe

Hanna

HI766F K-Type, High Temperature Probe

MX-12425

HI766PC K-Type, Penetration Probe

Hanna

HI766PC K-Type, Penetration Probe

MX-12431

HI766PD K-Type, Probe for Air and Gas

Hanna

HI766PD K-Type, Probe for Air and Gas

MX-12432

HI766PE1 K-Type, General Purpose

Hanna

HI766PE1 K-Type, General Purpose

MX-12433

HI766PE2 K-Type, General Purpose

Hanna

HI766PE2 K-Type, General Purpose

MX-12434

HI766TR1 K-Type, Long Penetration Probe

Hanna

HI766TR1 K-Type, Long Penetration Probe

MX-12435

HI768A Pt100-Type, 4-Wire Liquid / Gas

Hanna

HI768A Pt100-Type, 4-Wire Liquid / Gas

MX-12444

HI768L Pt100-Type, 4-Wire Air /Liquid

Hanna

HI768L Pt100-Type, 4-Wire Air /Liquid

MX-12445

HI768P Pt100-Type, 4-Wire Air / Semi-Solid

Hanna

HI768P Pt100-Type, 4-Wire Air / Semi-Solid

MX-12446

HI770710P – 7.01+10.01 pH@25°C – SQ – je 5x20ml COMBO

Hanna

HI770710P – 7.01+10.01 pH@25°C – SQ – je 5x20ml COMBO

MX-12454

HI77400C – 7.01+ 4.01 pH@25°C – SQ Zert. – je 5x20ml COMBO

Hanna

HI77400C – 7.01+ 4.01 pH@25°C – SQ Zert. – je 5x20ml COMBO

MX-12459

In-line Conductivity Probes with Platinum Ring

Hanna

In-line Conductivity Probes with Platinum Ring

MX-12939

Electrode selection guide

How to choose a pH electrode or probe

01

Meter and connector

State the meter model and the connector: BNC, DIN, Quick Connect DIN, RCA or a digital sensor. A meter expecting a digital electrode will not read an analogue one, and a mismatched connector makes an otherwise correct electrode unusable.

02

Sample and junction design

Describe the sample, not only the parameter. A double-junction reference places a second barrier between the reference electrolyte and samples carrying sulfides, proteins or heavy metals that would poison a single junction. Samples with solids or high viscosity call for an open junction or a clog-prevention design.

03

Body material and tip shape

Glass bodies resist solvents and are the general laboratory choice; plastic bodies are used where breakage is a hazard, in the field, or in food production. Flat and spear tips exist for surfaces and semi-solids, where a conventional bulb cannot make proper contact.

04

Temperature measurement

Say whether temperature compensation must come from the electrode itself or from a separate probe. A built-in sensor removes an item from the bench but ties temperature and pH to one replacement cycle.

05

Maintenance and consumables

An electrode is a consumable with a service life, not a permanent fitting. Budget storage solution, the correct filling solution for refillable types, cleaning solutions matched to the fouling, and membrane caps where a dissolved oxygen probe is used.

Include this in an electrode request

  • Meter model and connector type
  • Parameter: pH, ORP, conductivity, DO or ISE
  • Sample description, including solids and viscosity
  • Temperature range and whether compensation is required
  • Single or double junction, refillable or gel-filled
  • Storage, filling and cleaning solutions

Common electrode questions

Will any pH electrode fit my meter?

No. The connector (BNC, DIN, Quick Connect or a digital sensor) decides compatibility before any other property of the electrode. Send the meter model with the request and this gets checked first.

Single or double junction: how do I choose?

From the sample. A double junction adds a barrier between the reference electrolyte and the sample, which is the usual choice where sulfides, proteins or heavy metals are present and would poison a single-junction reference.

Glass body or plastic body?

Glass is the general laboratory choice for chemical resistance. Plastic is used where breakage is a hazard, in the field, or in food production. Body material is a separate question from tip shape, which follows the physical form of the sample.

How long should a pH electrode last?

It is a consumable, and service life depends on the sample, temperature and storage rather than a fixed period. Keep storage solution on hand: a pH electrode should never be left dry or standing in deionised water, as both shorten its life.

What the electrode connects to

Buying notes

Nothing above restates a manufacturer specification. Junction design, body material, operating range and service life are specific to the electrode, and compatibility is confirmed against the meter and sample you give us.

Specifications, compatibility and supplied documents vary by model and option. Check them against your method and the current manufacturer data sheet before ordering. Supplying equipment does not validate a method or certify compliance.