Skip to content
ไทย

pH meter

pH, conductivity and TDS meters only — pen, portable and benchtop — from Ohaus (ST20, ST300, AB23PH-F, AB33EC-F), Mettler Toledo FiveEasy F20 and FiveGo F2, Eutech PH1710 and CON150, Hanna, Bante and HM Digital, plus Takemura and Rapitest soil testers. Buffers and electrolyte solutions sit under Consumables & Reagents, replacement electrodes under Electrodes & Probes. Free quotation, fast reply.

Buyer guide

Choose the meter, sensor and standards as one measurement system

For a Thai QC laboratory or production team, a useful quotation names the meter, compatible sensor and calibration supplies together. Start with the sample and acceptance requirement, then compare range, uncertainty or accuracy specifications, and the records your method needs.

See the checklist and buying questions

388 products · page 5 of 9

HI6006 – 6.000 pH@25°C – MQ – 500ml

Hanna

HI6006 – 6.000 pH@25°C – MQ – 500ml

MX-12054

HI6011 – 11.000 pH@25°C – MQ – 500ml

Hanna

HI6011 – 11.000 pH@25°C – MQ – 500ml

MX-12063

HI6012 – 12.000 pH@25°C – MQ – 500ml

Hanna

HI6012 – 12.000 pH@25°C – MQ – 500ml

MX-12064

HI6013 – 13.000 pH@25°C – MQ – 500ml

Hanna

HI6013 – 13.000 pH@25°C – MQ – 500ml

MX-12065

HI6016 – 1.679 pH@25°C – MQ – 500ml

Hanna

HI6016 – 1.679 pH@25°C – MQ – 500ml

MX-12066

HI6068 – 6.862 pH@25°C – MQ – 500ml

Hanna

HI6068 – 6.862 pH@25°C – MQ – 500ml

MX-12073

HI6074 – 7.400 pH@25°C – MQ – 500ml

Hanna

HI6074 – 7.400 pH@25°C – MQ – 500ml

MX-12074

HI61008xx – AmpHel Prozess pH Elektrode

Hanna

HI61008xx – AmpHel Process pH Electrode, PVDF

MX-12079

HI6101605 – AmpHel Prozess pH Elektrode

Hanna

HI6101605 – AmpHel Process pH Electrode, PVDF, 5 m Cable

MX-12081

HI6124 – 12.450 pH@25°C – MQ – 500ml

Hanna

HI6124 – 12.450 pH@25°C – MQ – 500ml

MX-12082

HI62911D – pH/°C Electrode

Hanna

HI62911D – pH/°C Electrode

MX-12084

HI6493005 – pH Industrieelektrode

Hanna

HI6493005 – pH Industrieelektrode

MX-12087

HI70006C – 6.86 pH@25°C – SQ Zert. – 25x20ml

Hanna

HI70006C – 6.86 pH@25°C – SQ Zert. – 25x20ml

MX-12092

HI70006P – 6.86 pH@25°C – SQ – 25x20ml

Hanna

HI70006P – 6.86 pH@25°C – SQ – 25x20ml

MX-12093

HI7001L – 1.68 pH@25°C – SQ – 500ml

Hanna

HI7001L – 1.68 pH@25°C – SQ – 500ml

MX-12102

HI70030C – EC 12880 μS/cm@25°C Zert. – 25x20ml

Hanna

HI70030C – EC 12880 μS/cm@25°C Zert. – 25x20ml

MX-12105

HI70030P – EC 12880 μS/cm@25°C – 25x20ml

Hanna

HI70030P – EC 12880 μS/cm@25°C – 25x20ml

MX-12106

HI70031C – EC 1413 μS/cm@25°C Zert. – 25x20ml

Hanna

HI70031C – EC 1413 μS/cm@25°C Zert. – 25x20ml

MX-12107

HI70031P – EC 1413 μS/cm@25°C – 25x20ml

Hanna

HI70031P – EC 1413 μS/cm@25°C – 25x20ml

MX-12108

HI70032C – 1382 mg/l (ppm) TDS@25°C Cert. – 25x20ml

Hanna

HI70032C – 1382 mg/l (ppm) TDS@25°C Cert. – 25x20ml

MX-12109

HI70032P – 1382 mg/l (ppm) TDS@25°C – 25x20ml

Hanna

HI70032P – 1382 mg/l (ppm) TDS@25°C – 25x20ml

MX-12110

HI70038C – 6.44 g/l (ppt) TDS@25°C Zert. – 25x20ml

Hanna

HI70038C – 6.44 g/l (ppt) TDS@25°C Zert. – 25x20ml

MX-12111

HI70038P – 6.44 g/l (ppt) TDS@25°C – 25x20ml

Hanna

HI70038P – 6.44 g/l (ppt) TDS@25°C – 25x20ml

MX-12112

HI70039C – EC 5000 μS/cm@25°C Zert. – 25x20ml

Hanna

HI70039C – EC 5000 μS/cm@25°C Zert. – 25x20ml

MX-12113

HI70039P – EC 5000 μS/cm@25°C – 25x20ml

Hanna

HI70039P – EC 5000 μS/cm@25°C – 25x20ml

MX-12114

HI7006/1G – 6.86 pH@25°C – SQ – 3.78L

Hanna

HI7006 6.86 pH@25°C – SQ

2 variants: 1G / 3.78L · 1L / 1000ml

Choose a variant
HI7006L – 6.86 pH@25°C – SQ – 500ml

Hanna

HI7006L – 6.86 pH@25°C – SQ – 500ml

MX-12132

HI70080C – 800 mg/l (ppm) TDS@25°C Zert. – 25x20ml

Hanna

HI70080C – 800 mg/l (ppm) TDS@25°C Zert. – 25x20ml

MX-12138

HI70080P – 800 mg/l (ppm) TDS@25°C – 25x20ml

Hanna

HI70080P – 800 mg/l (ppm) TDS@25°C – 25x20ml

MX-12139

HI7030/1G – EC 12880 μS/cm@25°C – 3.78L

Hanna

HI7030/1G – EC 12880 μS/cm@25°C – 3.78L

MX-12165

HI7030L – EC 12880 μS/cm@25°C – 500ml

Hanna

HI7030L – EC 12880 μS/cm@25°C – 500ml

MX-12167

HI7031/1G – EC 1413 μS/cm@25°C – 3.78L

Hanna

HI7031/1G – EC 1413 μS/cm@25°C – 3.78L

MX-12170

HI7031L – EC 1413 μS/cm@25°C – 500ml

Hanna

HI7031L – EC 1413 μS/cm@25°C – 500ml

MX-12172

HI7032L – 1382 mg/L (ppm) TDS @25°C – 500ml

Hanna

HI7032L – 1382 mg/L (ppm) TDS @25°C – 500ml

MX-12176

HI7033L – EC 84 μS/cm@25°C – 500ml

Hanna

HI7033L – EC 84 μS/cm@25°C – 500ml

MX-12179

HI7034L – EC 80000 μS/cm@25°C – 500ml

Hanna

HI7034L – EC 80000 μS/cm@25°C – 500ml

MX-12182

HI7035L – EC 111800 μS/cm@25°C – 500ml

Hanna

HI7035L – EC 111800 μS/cm@25°C – 500ml

MX-12185

HI7039L – EC 5000 μS/cm@25°C – 500ml

Hanna

HI7039L – EC 5000 μS/cm@25°C – 500ml

MX-12192

HI7061L – Electrode Cleaning Solution (General) – 500ml

Hanna

HI7061L – Electrode Cleaning Solution (General) – 500ml

MX-12220

HI70631L – RfE – Fleisch – 500ml

Hanna

HI70631L – RfE – Fleisch – 500ml

MX-12224

HI70635L – RfE – Weinablagerungen – 500ml

Hanna

HI70635L – RfE – Weinablagerungen – 500ml

MX-12226

HI710007 Shockproof – rubber boot for portable meter – blue

Hanna

HI710007 Shockproof – rubber boot for portable meter – blue

MX-12294

HI770710C – 7.01+10.01 pH@25°C – SQ Zert. – je 5x20ml COMBO

Hanna

HI770710C – 7.01+10.01 pH@25°C – SQ Zert. – je 5x20ml COMBO

MX-12453

HI77100C – pH 7.01 + EC 1413 μS/cm @25°C – SQ Zert. – je 10x20ml COMBO

Hanna

HI77100C – pH 7.01 + EC 1413 μS/cm @25°C – SQ Zert. – je 10x20ml COMBO

MX-12456

HI77400P – 7.01+ 4.01 pH@25°C – SQ – Sachets 5x20ml COMBO

Hanna

HI77400P – 7.01+ 4.01 pH@25°C – SQ – Sachets 5x20ml COMBO

MX-12460

HI8314 Portable pH Meter

Hanna

HI8314 Portable pH Meter

MX-10301

HI8710 pH analog Controller with Self Diagnostic

Hanna

HI8710 pH analog Controller with Self Diagnostic

MX-12559

HI8711 Dual Setpoint – pH analog Controller with 4 to 20mA

Hanna

HI8711 Dual Setpoint – pH analog Controller with 4 to 20mA

MX-12560

Buyer guide

Five decisions to make before comparing models

01

Parameters, units and expected range

List pH and conductivity separately, including the expected range in µS/cm or mS/cm. If reporting TDS, record the conversion factor required by your method. A conductivity-derived TDS result does not identify individual dissolved substances.

02

Match the sample to the sensor

Give the sample type, temperature and container dimensions, plus the existing meter and connector if replacing a probe. A milk sample, a viscous product and low-conductivity water can need different sensor designs. Confirm the exact electrode and meter combination before ordering.

03

A catalog example: HI98130

The Hanna HI98130 listed in our catalog combines pH, EC, TDS and temperature. Its EC range is 0.00 to 20.00 mS/cm with 0.01 mS/cm resolution. That resolution equals 10 µS/cm, so a buyer needing finer low-conductivity readings should specify that requirement before choosing this high-range tester.

04

Budget for the calibration supplies

Choose buffers that cover the expected sample pH and that the meter recognizes. Include the required conductivity standard, electrode storage and cleaning solutions, and replacement-sensor needs. Ask for lot, expiry and certificates where required; an included starter sachet is not a recurring supply plan.

05

Field use, records and receipt

Specify portable or benchtop use, cable length, power and the output format you need. Ask the quotation to separate the instrument, sensor, standards and any calibration service. On receipt, check the model and kit suffix, included items and relevant certificates against the order.

Include this in the quote request

  • Sample or process, expected pH and conductivity range, and measurement temperature
  • Required resolution and accuracy specification, units and any TDS conversion factor
  • Existing meter model, sensor part number and connector, or a complete new system
  • Portable or benchtop use, container size, cable length and data-export needs
  • Buffers, conductivity standards, storage and cleaning solutions; required certificates
  • Quantity, delivery province, required-by date and procurement reference or TOR if used

Common pH and conductivity meter questions

Does 0.01 pH resolution mean ±0.01 pH accuracy?

No. Resolution is the displayed increment. For example, Hanna specifies 0.01 pH resolution and ±0.05 pH accuracy at 25 °C for HI98130. Compare both values and the conditions stated by the manufacturer against your method.

Can one instrument measure both pH and conductivity?

Yes, some models can. HI98130 is one catalog example, but the required ranges and sensor suitability still decide whether it fits. A combined tester does not make every pH electrode or conductivity application interchangeable.

Is a TDS reading the same as a chemical analysis of the water?

No. On a conductivity-based tester, TDS is calculated using a conversion factor. Document that factor when comparing results across instruments; use the relevant analytical method when you need the concentration of a particular substance.

Which buffers and accessories should appear in the quotation?

Request buffers that bracket the sample range and match the meter settings, the specified EC standard where needed, and suitable storage and cleaning solutions. State required pack sizes and certificates. Confirm the exact kit contents rather than assuming a meter includes a full year of consumables.

Continue the measurement setup

Official selection references

The HI98130 example follows its manufacturer specification. The buffer-selection references explain calibration range and solution care; the quoted sensor and method still determine the final setup.

This guide helps define a quotation. It does not replace your laboratory method, quality procedure or the current instructions for the selected instrument and sensor.